 MPO-45S Series
Si l O Single Output, 45W Compact, Open Frame AC/DC Power Supplies
Electrical Specifications
Key Features:
* 45W Output Power * Universal 90-264 AC Input * EN 60950 Compliant * Low Leakage Current * Nine Single Output Models * Meets EN55022 * >300 kHour MTBF * Only 5" x 3" x 1.1"
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Input Voltage Range Input Frequency Input Current Inrush Current Safety Ground Leakage Current Conditions Min. Typ. 90 127 47 See Model Selection Guide Cold Start, 115 VAC 15.0 Cold Start, 230 VAC 30.0 115 VAC 0.5 240 VAC 0.75 Universal Max. 264 370 63 Units VAC VDC Hz A Pk mA Max. Units
Output
Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz), See Note 2 Hold-Up Time Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 15 230 VAC 60 230 VAC 800 230 VAC 30 0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 118 Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Fixed Conditions Min. 3,000 1,500 500 Typ.
mSec mSec mSec %/C 135 166 Max. % % Units VAC
RoHS Compliant
General
Parameter Isolation Voltage Isolation resistance EMI/RFI
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
EMC Compliance Switching Frequency
100 M EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 65 kHz Units C C %
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Min. Typ. Max. -10 +25 +60 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient
Physical
Size Weight 5.00 x 3.00 x 1.10 Inches (127.0 x 76.2 x 28.0 mm) 6.7 Oz (0.19 kg) Conditions Min. Typ. Max. Units MIL HDBK 217F, 25C, Gnd Benign 300 kHours IEN 60950, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Reliability Specifications
Parameter MTBF Safety Standards Vibration
Model Selection Guide
Model Number MPO-45S-3.3 MPO-45S-05 MPO-45S-7.5 MPO-45S-12 MPO-45S-13.5 MPO-45S-15 MPO-45S-24 MPO-45S-27 MPO-45S-48 Input Current (A) 115 VAC 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 230 VAC 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 Output Voltage (VDC) Rated 3.3 5.0 7.5 12.0 13.5 15.0 24.0 27.0 48.0 Adjust 3.14 - 3.63 4.75 - 5.5 7.13 - 8.25 11.4 - 13.2 12.8 - 14.85 14.25 - 16.5 22.8 - 26.4 25.65 - 29.7 45.6 - 52.8 Current (A) Rated 8.0 8.0 5.4 3.7 3.3 3.0 1.9 1.7 1.0 Range 0 to 10.7 0 to 10.5 0 to 7.0 0 to 4.4 0 to 3.9 0 to 3.5 0 to 2.2 0 to 1.95 0 to 1.1 Output Tolerance (%) 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 2.0 Ripple & Noise
(mV p-p)
Efficiency
(%, Typ)
80 100 100 100 100 100 100 100 100
69 74 75 76 77 77 78 78 78
Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 F and a 47 F capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a "hiccup mode" circuit. The unit recovers automatically when the fault condition is removed. 4. Overload protection is provided by a foldback current limiting circuit. The unit recovers automatically when the fault condition is removed. For the 3.3V output model, overload protection is set to operate between 36 to 55W. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the mechanical diagram for the correct rating.
Mechanical Dimensions
Pin Connections: CN1 (Molex 5277-02 or equiv.)
Pin 1 2 Function Mating Housing Terminal AC-Neutral Molex 5195 Molex 5194 or Equiv. or Equiv. AC-Line
Pin Connections: CN2 (Molex 5273-06 or equiv.)
Pin 1, 2, 3 4, 5, 6 Function +Vout -Vout Mating Housing Terminal Molex 5195 Molex 5194 or Equiv. or Equiv. Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
Derating Curve Static Characteristics
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com